An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor

Herein, we report a non-enzymatic glucose sensor based on a metal-organic framework (MOF) as alternative approach for long-term glucose monitoring. Specifically, nickel-based MOFs were solvothermally synthesized using either 2-amino-1,4-benzenedicarboxylic acid (BDC-NH2) or 2-hydroxy-1,4-benzenedica...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Hoofdauteurs: Daud, A.D., Lim, H.N., Ibrahim, I., Endot, N.A., Gowthaman, N.S.K., Jiang, Z.T., Cordova, Kyle E.
Formaat: Artikel
Gepubliceerd in: Elsevier 2022
Tags: Voeg label toe
Geen labels, Wees de eerste die dit record labelt!
id oai:psasir.upm.edu.my:100232
record_format eprints
spelling oai:psasir.upm.edu.my:100232 http://psasir.upm.edu.my/id/eprint/100232/ An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor Daud, A.D. Lim, H.N. Ibrahim, I. Endot, N.A. Gowthaman, N.S.K. Jiang, Z.T. Cordova, Kyle E. Herein, we report a non-enzymatic glucose sensor based on a metal-organic framework (MOF) as alternative approach for long-term glucose monitoring. Specifically, nickel-based MOFs were solvothermally synthesized using either 2-amino-1,4-benzenedicarboxylic acid (BDC-NH2) or 2-hydroxy-1,4-benzenedicarboxylic acid (H2BDC-OH), both of which were characterized by different physicochemical techniques. The electrochemical performance of both electrodes towards glucose sensing was investigated and Ni-BDC-NH2 exhibited a significantly better electrocatalytic behaviour towards oxidation of glucose than bare Ni-BDC or Ni-BDC-OH in an alkaline media. This was attributed to a favourable multi-layered sheet-like structure that allowed diffusion for entrapment of glucose and the incorporation of –NH2 functional groups attached to the BDC linker which, were responsible for electrochemical adsorption of glucose molecules. Ni-BDC-NH2 displayed a lower detection limit (3.82 μM), higher stability (>180 days), and remarkable sensitivity (308 μA mM−1 cm−2). Additionally, a molecular sieve effect for Ni-BDC-NH2 led to a noteworthy anti-interference ability and the sensor displays a fast response time of 5.4 s towards glucose detection. These results indicate that the as-synthesized non-enzymatic glucose sensor operates with a longer lifetime and is viable for use as an intensive monitoring system. Elsevier 2022-09-15 Article PeerReviewed Daud, A.D. and Lim, H.N. and Ibrahim, I. and Endot, N.A. and Gowthaman, N.S.K. and Jiang, Z.T. and Cordova, Kyle E. (2022) An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor. Journal of Electroanalytical Chemistry, 921. art. no. 116676. pp. 1-9. ISSN 1572-6657 https://www.sciencedirect.com/science/article/pii/S1572665722006683 10.1016/j.jelechem.2022.116676
institution UPM IR
collection UPM IR
description Herein, we report a non-enzymatic glucose sensor based on a metal-organic framework (MOF) as alternative approach for long-term glucose monitoring. Specifically, nickel-based MOFs were solvothermally synthesized using either 2-amino-1,4-benzenedicarboxylic acid (BDC-NH2) or 2-hydroxy-1,4-benzenedicarboxylic acid (H2BDC-OH), both of which were characterized by different physicochemical techniques. The electrochemical performance of both electrodes towards glucose sensing was investigated and Ni-BDC-NH2 exhibited a significantly better electrocatalytic behaviour towards oxidation of glucose than bare Ni-BDC or Ni-BDC-OH in an alkaline media. This was attributed to a favourable multi-layered sheet-like structure that allowed diffusion for entrapment of glucose and the incorporation of –NH2 functional groups attached to the BDC linker which, were responsible for electrochemical adsorption of glucose molecules. Ni-BDC-NH2 displayed a lower detection limit (3.82 μM), higher stability (>180 days), and remarkable sensitivity (308 μA mM−1 cm−2). Additionally, a molecular sieve effect for Ni-BDC-NH2 led to a noteworthy anti-interference ability and the sensor displays a fast response time of 5.4 s towards glucose detection. These results indicate that the as-synthesized non-enzymatic glucose sensor operates with a longer lifetime and is viable for use as an intensive monitoring system.
format Article
author Daud, A.D.
Lim, H.N.
Ibrahim, I.
Endot, N.A.
Gowthaman, N.S.K.
Jiang, Z.T.
Cordova, Kyle E.
spellingShingle Daud, A.D.
Lim, H.N.
Ibrahim, I.
Endot, N.A.
Gowthaman, N.S.K.
Jiang, Z.T.
Cordova, Kyle E.
An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
author_facet Daud, A.D.
Lim, H.N.
Ibrahim, I.
Endot, N.A.
Gowthaman, N.S.K.
Jiang, Z.T.
Cordova, Kyle E.
author_sort Daud, A.D.
title An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
title_short An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
title_full An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
title_fullStr An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
title_full_unstemmed An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
title_sort effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
publisher Elsevier
publishDate 2022
_version_ 1819301168240656384
score 13.4562235